Pentair intellichlor cell light not on - PN 520590 Rev C - 042806.

 
To remove the cell, firstswitch offthe system pump and unscrew both unions. . Pentair intellichlor cell light not on

A 2014 cell even shut down for 1 years would still have met its life expectancy. When IntelliChlor cell is connected to an automation system, the cell sanitizer output will be adjusted through the panel menu, NOT the cell. comquestionsask Make sure you Subscribe so you get your answer intell. If your salt cell is older than that, it will stop producing chlorine. Learn about the structure of thin-film solar cells. Aim for 50 to 80 parts per million (ppm), as per. SW VA. Salt test strip shows water is 2700ppm. If the unit is powered correctly it only receives power when the pump is running -and as long as it is. A Low Salt indication on a Pentair IC, if the salt level in the pool is OK, is typically the flow sensor. This video demonstrates how to run through diagnostic mode on a Pentair salt cell, and what everything means. Cleaned Cell. Inspect cell light is not on before read more. A short to the point video explaining the functions of the Pentair Intellichlor system. The ICXX series runs on a 300 second cycle. 000 641 How to diagnose a Pentair ic-20, ic-30, ic-40, and ic-60 salt cell Craig Wooster 5. The salt chlorinator works with existing pump and filtration systems to reliably supply the swimming pool with pure chlorine, every day. Verify the ORP controller is opening and closing the dry-contact output. It provides the same sanitation performance as chlorine additives without the drawbacks of chlorine handling. Plus, it&39;s an easy drop-in replacement with guaranteed compatible connections for the Pentair IC-40 (as well as IC-20 and IC-60). Intellichlor IC40 with no power at the cell. Cell light is off so the unit is not producing chlorine at all due to very low salt level reading. Hi my Inteliclor chlorinator is blinking green and red under salt level and nothing in status. Page 27 shows you how to disconnect the line. When your Pentair Intellichlor Cell light is not on, it could be indicative of a problem with the cell. The IC40 that I have was replaced in November 2020 through Pentair. The flashing green light will now come on at 4000ppm. If you notice that the light is not illuminated, check to make sure that all connections are secured and power is flowing properly. A small amount of debris was present, easily removed with a. Worked when I opened the pool 6 weeks ago. But I have added salt and used salt testing kit and it shows salt at 3740ppm. I also got an increased reading the few times I've added salt. Unit is not producing Chlorine at that time. The IECG is not producing chlorine. Consult your experienced pool professional, who should be able to advise you on the proper material. 5 minutes (while the cell is at rest. Verify the salt level using the Taylor K-1766 salt test kit. After doing this the flashing stopped and it started producing chlorine again. IntellipH monitors the communication link between the IntelliChlor cell and automation system. With a salt chlorinator,. Pentair is not, however, responsible under this warranty for . The local Pentair dealer looked the the unit yesterday and said my salt readings were off, and that the salt level was at 4,000ppm, and that would cause the high salt indication on the Intellichlor. Should have mentioned the low light was flashing at the time and appears off but wasnt. May 3, 2014 57,278 Laughlin, NV Pool Size 6000 Surface Fiberglass Chlorine Salt Water Generator SWG Type Pentair Intellichlor IC-40. Wire the SWCG power center with a power cord (25&39; 14-3 outdoor extension cord, cut to length). Pentair Intellichlor Overview - IC15 IC20 IC30 IC40 IC60. It is possible that checking every 30 minutes, you just missed it. Furthermore, incorrect salinity levels, incorrect pH levels, an aging cell, and inadequate flow due. Pentair Water Pool and Spa, Inc. The local Pentair dealer looked the the unit yesterday and said my salt readings were off, and that the salt level was at 4,000ppm, and that would cause the high salt indication on the Intellichlor. Dec 4, 2016. My water measures 3500ppm with a temp compensated gauge, but the intellichlor (through easy touch) reads the salt as 2600ppm. The "cell" light will only come on when it's making chlorine. Ordered a new assembly on Amazon for 20. Sep 15, 2017. I also got an increased reading the few times I've added salt. electrical source so that the electrolytic cell only operates when the pool pump is on. Consult your experienced pool professional, who should be able to advise you on the proper material. That set up is not advisable. control system , the IntelliChlor AC power center wires must be connected to. To troubleshoot, first check the salt. At 50, if the light never goes out something is wrong with the cell. If I am adding a bag or two of salt I don't lower the . , Moorpark, CA 93021. onoff cycles, this light will cycle on and off. Thing is, the salt level reported by screenlogic and tested at the pool store is good (3350), and the flow is fine (see waterfall on video). No need to buy, transport and store chlorine compounds. So initially I thought, ok and added a bag of salt which took salt too high I later discovered (around (4300-4500). Ensure the water temperature is above 52&176; F. They are easy to fix. Replace the fuse at the bottom of the power center. The cell use that voltage based on the water temp to find out the salt. We just had some salt cells requiring maintenance. Theres now an alternative to buying, handling and storing chlorine. If it goes Green, double check all the valve positions. If the unit is powered correctly it only receives power when the pump is running -and as long as it is plugged in it should be showing lights. The cell's temp sensor is part of the Flow Switch assy, which are known to be flaky. If this is the case, the salt level on the cell will need to be recalibrated. IC20 Cell (PN 520554) Designed for pools up to 20,000 U. At 50 output, the cell light will be on solid green for 2. Pentair Pool Quick Link for PartsEquipment httpsamzn. About 500 on amazon or ebay for new ic40. Pentair Intellichlor IC-40 May 23, 2023; Add bookmark 2 According to my IC40 manual, the flashing green cell light means the scg needs to be inspected. Goob 0. PB is checking if Pentair is willing to extend warranty support but wasn't hopeful about parts availability and such. Water Pool and Spa&174; IntelliTouch&174;, EasyTouch&174; or SunTouch&174; automation. My Pentair Intellichlor cell still has a flashing green light after I have taken it off and cleaned it 2 times by acid washing the cell (so it longer bubbles and looks clean now). If it's under warranty, give Pentair a call. Is the "Cell" light on your IntelliChlor green or not. But I have added salt and used salt testing kit and it shows salt at 3740ppm. 5 minutes, etc. Jul 9, 2019 Check Cell Light Flashing This problem occurs typically in salt cells over 5 years old. Safety Equipment. IntelliChlor Optical Reader User&x27;s Guide Introduction The IntelliChlor diagnostic optical reader is a wireless optical reader device used to retrieve stored operating data from the IntelliChlor chlorine generator to a PC or PDA. Acid washing also reduces cell life and I think the 5050 is pretty strong, it should be 1 part acid to 4 parts water or less. EasyTouch IntelliTouch SCG Power Supply Replacement Parts Installation Guide IntelliChlor SCG Power Supply Replacement Parts Removal and Installation To remove the EasyTouchIntelliTouch load center high voltage panel. So its not producing chlorine. Jun 7, 2017. means there is a potential that the unit needs cleaning. The FLOW light should turn green. Motors - Replacement. It is a Pentair Intelleconnect. webarnes99; Jun 21, 2023; Salt Water Chlorine Generators (SWG). So its not producing chlorine. CAUTION - Install the IntelliChlor unit a minimum of 0. Ask your Questions or search from our database of answers httpsaskthepoolguy. 8 or higher pure NaCl) not included in kit 1. Power to the cell is 28VDC read more. 7&176;C) CELL light will be off. Jul 7, 2014. July 18, 2016 Ask the Pool Guy. Jul 26, 2006 I set the IC20 to superchlorinate for 24 hours 100. Had water tested and 4200 is the current salt level in the pool. will light the red LOW SALT indicator, and the CELL light will go blank, indicating there is not. Remove any debris clogging the strainer basket and clean the pool filter if the flow light is red. Thing is, the salt level reported by screenlogic and tested at the pool store is good (3350), and the flow is fine (see waterfall on video). M, Logically, you either have flow or not. Hi, New pool owner here, my brand new IC-20 has been running fine most of the time, but I get a notification (e-mail) of communication lost from my intellicenter 2 or 3 times a day, it stops producing chlorine (cell led turns off) and both the good (green) and low (red) LEDs flashes. Second check power going to the transformer you should have 240VAC or 120VAC. The most common reason for a Pentair salt cell not producing chlorine is improper maintenance. Ultraviolet & Ozone. After only a few months, the flowsensor switch was replaced 2 times and then the unit started leaking. The salt light was flashing when I first installed so I drained some water to lower the salt. If your salt cell has any lights on, when in the Service Mode, then it is not correctly wired to the Load side of the PumpFilter relay as it should be per the warning on the SWCG's Transformer. Silver Supporter. I have a Pentair IntelliChlor salt system. The new unit Is only a few months old and has had its switch replaced once already. Power to the cell is 28VDC read more. The IECG needs to be inspected. 7K views, 14 likes, 0 loves, 1 comments, 4 shares, Facebook Watch Videos from Pool Specialists We just uploaded another informative video yo youtube. the cell is not powered down, the cell reading from the Wand will be a stored value from the last time the cell checked for salt, possible 12 hours ago. 7&176;C) CELL light will be off. Sometimes water will get into the interstitial layer and short out the electronics Check for power at the cell cord connection to the power supply. CAUTION - To reduce the risk of electric shock, install IntelliChlor cell at least 5 feet from the inside wall of the pool. I have internal board Pentair Water PCBA 521593. Sep 15, 2017. My Pentair Intellichlor cell still has a flashing light My Pentair Intellichlor cell still has a flashing green light after I have taken it off and cleaned it 2 times by acid washing the cell (so it longer bubbles and looks clean now). Mar 2, 2011 40,365. gallons (75,000 liters). Enter field calibration mode. Apparently it goes on for 59 minutes and rests for 1 minute (cell light is on when producing chlorine). Power offrestart i9 twice. Flow Switch is RED - Make sure filter cartridge, pump basket is all clean. The cell light comes on when I set it, but if I check on it 5-10 minutes later the cell light is off, it eventually comes on again but not for long, maybe 2 minutes and then it goes off. Verifying if the IntelliChlor Cell is Generating. Fixreplace your saltwate. The automation system is showing 0 salt level. The Intellichlor IC40 Cell Light is a saltwater chlorinator that uses electrolysis to produce chlorine from dissolved salt. Details can be seen in this post; Pentair IntelliChlor IC40 Fire Burning. 4, TA 110, and salt 3000. Oct 5, 2020 Drill a hole in the pipe, stick in the probe, and use a hose clamp to hold it in place. At 50 the Cell light should be on for 2. Pentair Intellichlor IC-40 Apr 21, 2021;. If still incorrect continue on to calibration steps. So the cell is just about 8 months old and the cell light is flashing. It is possible that checking every 30 minutes, you just missed it. Sometimes when a salt cell goes bad the lights all go out. An IntelliChlor Salt Chlorinator system consists of one or more of the following PC100 (PN 520556) Power Center Kit. Normally, 5-7 years if properly sized and water chemistry managed. com has the largest selection of swimming pool and spa replacement parts with over 70,000 parts in stock. CAUTION - Install the IntelliChlor unit a minimum of two (2). If you have a Pentair Intellichlor and the status light is not turning on, one of the first things to check is whether or not there is power being supplied to it. show it's fully operational. 00 Sale. High Amperage Ensure that current draw is not exceeding 30 amps on 230V systems or 15 amps on 115V. Noticed my chlorine generator did not turn on today so hoping someone can help me troubleshoot. As I said, there is a way to replace the sensor DYI, but if it's under warranty, let them do it. ly2TTahSdThe Ultimate. Raytrey; Aug 12, 2023; Salt Water Chlorine Generators (SWG). Hello Carlos - The status mode test seems to indicate that the cell is at least 10,000 hours old and it's time to replace the cell. TFP Expert. Replacement Cell compatible with Pentair&174; IntelliChlor&174; IC20&174; 520554 Cells (Aftermarket Cell) 720. Plus, it's an easy drop-in replacement with guaranteed compatible connections for the Pentair IC-40 (as well as IC-20 and IC-60). Pentair Water Pool and Spa, Inc. In this video I give an overview of how most saltwater chlorinators work. 1,028 Satisfied Customers. Edahl - Yes, I would unplug the black power line to the cell before cleaning. If you run the IC40 cell at 40, you can probably run the IC60 cell at 20 and produce the same amount of chlorine. sand filter shows higher than usual pressure, I&39;m suspecting it&39;s dirty, not sure when is the last time sand was replaced. The IntelliChlor takes a new salt reading at every power up and after every 12 hours of cell run time. Assuming you have good flow, then I like your idea of connecting the redblack coming out of the cell and ensuring that the red no flow light turns green. IC20 and IC40 are compatible with IntelliPool & Soleo VS For residential. Add cyanuric acid to the water of an outdoor pool if the chlorine level is lower than it should be. com for more information about. Worked when I opened the pool 6 weeks ago. If this is the case, the salt level on the cell will need to be recalibrated. The ICXX series runs on a 300 second cycle. My Pentair IC40 generator has had the low salt light on all season since opening up. It is not covered under warranty. Wire the SWCG power center with a power cord (25&39; 14-3 outdoor extension cord, cut to length). Pentair Intellichlor IC-40 May 23, 2023; Add bookmark 2 According to my IC40 manual, the flashing green cell light means the scg needs to be inspected. Once the water temp gets near 52 or so the cold light comes on and the cell shuts off. You will see the lights go crazy and at the bottom it will spit out a number of lights along the output (the five lights at the bottom). If it is set for 60 the cell light will be off for 40 of it&x27;s run time. Lights - Pool & Spa. The ICXX series runs on a 300 second cycle. Sep 15, 2017. If the automation system sends out a 0 output. I have confirmed that it is NOT generating. SWG Type. Bedford, TX. IC20 and IC40 are compatible with IntelliPool & Soleo VS For residential. The Intellichlor operates on a series of. IC20 and IC40 are compatible with IntelliPool & Soleo VS For residential. this condition lasts for 30 seconds. Jul 17, 2017 Remove any debris clogging the strainer basket and clean the pool filter if the flow light is red. It is solid green when functioning and off when in the sanitizing cycle. It is recommended that a pool pump timer be used to save on energy and prolong the service life of your pool pump and IntelliChlor. If I am adding 10 bags at the beginning of the season I have the cell. Intellichlor was acid cleaned a week prior to this occuring. About 500 on amazon or ebay for new ic40. Dec 4, 2016. Primary cell reads salt levels and communicates to all secondary cells. Add cyanuric acid to the water of an outdoor pool if the chlorine level is lower than it should be. Sometimes when a salt cell goes bad the lights all go out. High salt concentrations in water. The highest IC reading has occurred when the water temp was in the low 90's. So if your percentage is 50 then the cell light will be on about 2. Corrosion of the titanium plates within the cell, requiring cleaning or replacement. The green cell light is flashing and the pool has no chlorine. A small amount of debris was present, easily removed with a. I also added a little salt to bring it closer to 3600, which is recommended by Pentair. I also added a little salt to bring it closer to 3600, which is recommended by Pentair. Jun 9, 2012. This video demonstrates how to run through diagnostic mode on a Pentair salt cell, and what everything means. Intellichlor salt light shows red, low salt, and cell light is off. Today, I observed more closely. Motors - Replacement. Have all Pentair equipment EasyTouch, SuperFlo 1. Essentially, it means that the cell has reached its maximum amount of running hours and needs to be replaced. Bedford, TX. Possible causes include a low salt level, poorly balanced pH, clogged cells, high flow rates, electrical problems, or mineral build-up. TFP Expert. When the Power Center is switched on, the power LED is lit. The IntelliChlor chlorine generator may require additional steps to reset depending on the make and model. Additionally, no PIP. Normally, 5-7 years if properly sized and water chemistry managed. Back to Step 1 above. Low Flow. No Flow light coming on probably means the cells flow switch. Fixreplace your saltwate. Contractor&39;s Assistant Who manufactured the pool In ground - don&39;t know the pool manuf. 4, TA 110, and salt 3000. the cell is not powered down, the cell reading from the Wand will be a stored value from the last time the cell checked for salt, possible 12 hours ago. It is suitable for people with sensitive skin. Essentially, it means that the cell has reached its maximum amount of running hours and needs to be replaced. Pentair specifically says on page 9 int the IntelliChlor SWG Manual - CAUTION The use of dry acid (sodium bisulfate) till adjust pool pH is discouraged especially in arid regions where pool water is subject to excessive. electrical source so that the electrolytic cell only operates when the pool pump is on. Enter field calibration mode. The lack of a Status Light does not hinder the functioning of the Intellichlor IC40. Page 2 This cell must only be used on this model of chlorine generating device. Even if turn the percentages to 100 the cell light does not turn on. This video demonstrates how to run through diagnostic mode on a Pentair salt cell, and what everything means. 16 candles gif, newhaven craigslist

Jun 19, 2019. . Pentair intellichlor cell light not on

 Install the IntelliChlor according to the water flow arrow, displayed on the top of the cell. . Pentair intellichlor cell light not on katara porn

The Pentair iChlor is a great salt water system and the control panel is very user friendly. Power offrestart i9 twice. The green cell light is blinking for inspect cell. Looked at the pentair instruction manual. Buy in monthly payments with Affirm on orders over 50. Advertisement Because structure and function are so. Pentair Intellichlor IC-60 Nov 6, 2022; Add bookmark 4 You turn an IntelliChlor cell off by setting it to 0 so CELL light is off. Wear and tear due to continuous use. Reviews Questions Transform Pools with Ordinary Table Salt IntelliChlor uses common table salt to effectively and automatically produce chlorine a pool needs. Cell blades rated for 10,000 hours of operation five years of reliable chlorine output under normal operating conditions ;. This means it&x27;ll last you 3 to 5 years easily. My Pentair intellichlor cold water light is on even thought the water is warm. Possible causes include a low salt level, poorly balanced pH, clogged cells, high flow rates, electrical problems, or mineral build-up. is being produced, if off, the unit is in the off mode. In this video I give an overview of how most saltwater chlorinators work. 7&176;C) CELL light will be off. 5 minutes and then off for 2. Paint - Pool & Deck. M, Logically, you either have flow or not. It was cleaned with muriatic acid. Ordered a new assembly on Amazon for 20. Look at the bottom side of the cell for a tag with the Mfg. Pentair Intellichlor IC40. Safety Equipment. Item No. Oct 15, 2019 Check the manufacturing date to see how old the cell is. Aim for 50 to 80 parts per million (ppm), as per. pH 7. Since the wires are already open you. Jul 18, 2016 Salt Cell Troubleshooting with Pentair on the intellichlor ic20 or ic40 July 18, 2016 Ask the Pool Guy We just had some salt cells requiring maintenance. Thing is, the salt level reported by screenlogic and tested at the pool store is good (3350), and the flow is fine (see waterfall on video). The salt level is steady red (low). Palisade cells are found in the mesophyll of a leaf and their main function is the absorption of light so that photosynthesis can take place. Re Installing Pentair IntelliChlor (salt cell) 1. Paint - Pool & Deck. It will blink if you cell has scale build up inside. The scg is the salt cell. Jul 26, 2006 I set the IC20 to superchlorinate for 24 hours 100. In this video I give an overview of how most saltwater chlorinators work. It is not covered under warranty. ColorCascade LED Light Bubbler · Intellibrite 5g LED lighting · IntelliChlor. Disconnect the IntelliChlor or iChlor power cable from the power center. Pentair Intellichlor IC40. Normally to clean the cell perfectly, you need to plug the end that doesn't have the flow switch in it, then stand the cell up and pour in a 5050 solution of acid and water and make sure you fill it up past the flow switch so that it cleans all the sensors off as well. Intellichlor salt light shows red, low salt, and cell light is off. A Low Salt indication on a Pentair IC, if the salt level in the pool is OK, is typically the flow sensor. When the lights finish scrolling, the percent lights indicate hours of usage in 1,000s. Assuming you have verified the transformer has power going into the IC40 cell, it&39;s time to replace the cell. The salt level is steady red (low). The salt light was flashing when I first installed so I drained some water to lower the salt. The following steps will provide a guide on how to recalibrate a Pentair Intellichlor. The cell light flashes when it thinks the cell is dirty with scale. May 23, 2015 23,660 Tucson, AZ Pool Size 16000 Surface Plaster. I had a pentair intellichlor ic40 installed last summer. It is the after market Optimum Pool Technologies Switch. Intellichlor by Pentair Cell Light not on and other issues I have a pentair easytouch sysytem IntelliChlor - the cell light is not on (the cell was cleaned). The Pentair iChlor30 electronic chlorine generator is a salt pool system with integrated controls and cell. Their pool is only 10,000 gallons however the contractor installed an IC40. If you have any questions please contact us thr. The cell use that voltage based on the water temp to find out the salt. IntelliChlor Optical Reader Users Guide Introduction The IntelliChlor diagnostic optical reader is a wireless optical reader device used to retrieve stored operating data from the IntelliChlor chlorine generator to a PC or PDA. Pentair Intellichlor IC-40 May 23, 2023; Add bookmark 2 According to my IC40 manual, the flashing green cell light means the scg needs to be inspected. This instructional video demonstrates what to do to fix your salt cell if it does not display any lights. Corrosion of the titanium plates within the cell, requiring cleaning or replacement. Possible causes include a low salt level, poorly balanced pH, clogged cells, high flow rates, electrical problems, or mineral build-up. All lights go out for a second or two. The aftermarket replacement salt cell compatible with Pentair IntelliChlor models is a great way to upgrade your salt chlorinator system while replacing your old Pentair salt cell. Maintenance Items. 7C) CELL light will be off. A blinking light indicates that the cell needs attention. Pentair Intellichlor IC-60 Apr 20, 2019; Add bookmark 4 peterl1365 said Around 3500-4000. 3 Years iChlor Salt Chlorine Generator - Bundle with Power Supply and Cell (iChlor 15 and iChlor 30) - manufactured after October 1, 2023. May 12, 2023 After Powering Up IntelliChlor After powering up the IntelliChlor SCG, the light sequence at power up will be Salt lights will scroll back and forth, showing salt has not been checked yet COLD WATER light will be off (unless water temperature is below 52F -3F (11C -1. Cleaning Stand (fits Pentair&174; IntelliChlor&174; Salt Systems). Pentair Salt Cell Troubleshooting Guide Salt Cell SN Items to bring New Salt Cell Plug-in Power Center EasyTouch Salt PCB IntelliTouch Salt PCB Flow Switches 10amp Fuses In-Line Fuse Holder and wire crimps Union O-Rings Cleaning Cap Tools to bring Union Channel Locks 18 Screw Driver 14 Screw Driver. I put ph down in the pool, but it has not changed levels. It read 60 which means 6000 hours, and the chlorinator only has a life of 10,000. Abnormally dark or light skin is skin that has turned darker or lighter than normal. In conclusion, the Pentair Intellichlor Cell Light Flashing Green indicates that the cell is operating in normal conditions. Have all Pentair equipment EasyTouch, SuperFlo 1. Cell is clogged with debris or pump has lost prime. Should one of the secondary chlorinating cells become non-operational, the remaining cells continue to function without interruption. Water temperature in excess of 100&176; F (37. Would changing the flow switch correct these. Apparently it goes on for 59 minutes and rests for 1 minute (cell light is on when producing chlorine). Intellichlor salt light shows red, low salt, and cell light is off. Oct 5, 2020 Drill a hole in the pipe, stick in the probe, and use a hose clamp to hold it in place. Pentair IntelliChlor IC40 Cell EC-520555 EC-520555 is the online version of 520555 IntelliChlor IC40 Cell which is a TradeGrade product and is sold only in brick and mortar stores. Pentair - EC-520555 - IC40 IntelliChlor Replacement Salt Cell - Limited Warranty. IC20 Cell (PN 520554) Designed for pools up to 20,000 U. Pentair intellichlor ic40 cell light not lit except during super chlorination mode. Same sanitation performance as manual chlorine addition without the drawbacks. The Light needs to get power from the load side of an AUX relay, not the PumpFilter relay. IC15 External Power Supply. I had who water tested and that salt level - Answered according an verified Pool and Spa Expert. I have cleaned the unit and reset it by disconnecting the power. 00 520. The "cell" light will only come on when it&39;s making chlorine. If you notice that the light is not illuminated, check to make sure that all connections are secured and power is flowing properly. Then hit the decrease to the 40. If the indicator lights go out on a pentair Ic40 intellichlor must the cell be replaced or is it still producing chlorine just not showing it on the light panel or is this a flow switch problem. Normal lights are lit green. Ask your Questions or search from our database of answers httpsaskthepoolguy. The Intellichlor operates on a series of. comquestionsask Make sure you Subscribe so you get your answer intell. The IECG is not producing chlorine. Then cut the green and white wires in the flow switch. My Pentair intellichlor cold water light is on even thought the water is warm. M, Logically, you either have flow or not. Essentially, it means that the cell has reached its maximum amount of running hours and needs to be replaced. I drained about 10" of water from the pool yesterday, and will finish filling tonite (hopefully). If the red flow light is lit, the SWCG "thinks" there is little or no water flowing through it and will no operate, no matter what. All lights on the IC40 are off. No Flow light coming on probably means the cells flow switch. Hello Carlos - The status mode test seems to indicate that the cell is at least 10,000 hours old and it's time to replace the cell. Contractor's Assistant Who manufactured the pool In ground - don't know the pool manuf. So the cell is just about 8 months old and the cell light is flashing. Now I am showing a green flow light but the salt level is indicating 0 PPM. The cell light flashing green means something is preventing the cell from working correctly. The cell light flashing green means something is preventing the cell from working correctly. If the cell light passes this test, then the cell is making chlorine. . how to get all gloves in slap battles